Internal signage at EV-charging points

Front and rear equal sign, double-sided (see also floorplan)

Application:

  • Signage EV-charging suspended perpendicular to driving aisle for visibility

    • Position aligned with front of parking space at heart of a single space

  • EV-charging device (wall mounted), colour reference neutral light colour

    • Position always between parking spaces and never at heart of a single space

    • Bottom of EV-charging device at 800mm+floor

    • Power supply via ceiling

Specifications:

  • Panel:

    • Panel (double-sided) glued on 18mm wbp plywood,
      at lateral side & joints plywood painted RAL9005 jet black

    • Dibond plate (2mm) (www.Dibond.eu), platinum white (~RAL9016) matt (double-sided)

    • Foil on plate: 3M 3630-57 olympic blue / Oracal 8500-53 light blue (double-sided)

    • Signage cut out of blue foil

  • Dimensions:

    • Height = 300mm

    • Width = 300mm

  • Q-drawings:

    • Q.32.A Signage, suspended

    • Q.32.B Signage, mounting on ceiling

Section

Floorplan

Internal signage at EV-charging points (A1-frame)

Application:

  • A1-frame (wall mounted) for communication EV-charging

  • Position always between parking spaces and never at heart of a single space

  • Minimal 1x A1-frame per 4 CPs where CPs are located

Specifications:

  • A1-poster:

    • Poster size: height x width = 832 x 593mm

    • Poster layout: CPO branded & mandatory information:

      • Clear CP usage instructions (start/stort session, unplug etc.)

      • CPO customer helpdesk phone number and e-mail

      • Tariff information reference (where to find charging tariffs?)

      • Location of the specific charge point ID (reference number)

      • Explain functionalities (indicator/display colours)

      • Optional subtle co-branding with Q-Park (not preffered)

  • Dimensions A1-frame:

    • Height = 924mm

    • Width = 690mm

  • Q-drawings:

    • Q.33.B Signage A1-frame, wall fastening

Section

Floorplan

Internal signage at EV-charging points (optional signage)

Example

Example

Example

Application:

  • Only applicable in case legally binding message is needed

  • In order to distinct regular CPs (AC<11kW) with fast CPs (DC>22kW) where applicable

  • Sign preferably wall mounted (top of sign = top of A1-frame)

  • Position always at heart of the EV-charging space

  • 1 sign per parking space

Specifications:

  • Panel:

    • Panel (single-sided) glued on 18mm wbp plywood
      At lateral side and joints plywood painted RAL9005 jet black

    • Dibond plate (2mm) (www.Dibond.eu), platinum white (~RAL9016) matt

    • Foil on plate: 3M 3630-57 olympic blue / Oracal 8500-53 light blue

    • Signage cut out of blue foil

  • Dimensions:

    • Height = 300mm

    • Width = 610mm

  • Q-drawings:

    • Q.33.A Signage, wall fastening

Section

Floorplan